Reset Search
 

 

Article

Error received when add an MLT to a VLAN

« Go Back

Information

 
TitleError received when add an MLT to a VLAN
Objective
  • Error received when add an MLT to a VLAN
FA_server_vsp4k-01:1(config)#mlt 8 vlan 96 

Error: Switched UNI/Fabric attach enabled mlt cannot be part of any vlan
Environment
  • VSP
  • All versions
Procedure
  • You must to disable FA on MLT 8 first, then add the MLT to the Vlan, then enable FA again. 

Disable FA on MLT 8 
FA_server_vsp4k-01:1(config)#interface mlt 8 
FA_server_vsp4k-01:1(config-mlt)#no fa

Add MLT 8 to Vlan 
FA_server_vsp4k-01:1(config-mlt)#mlt 8 vlan 96

Enable FA on MLT 8 
FA_server_vsp4k-01:1(config)#interface mlt 8 
FA_server_vsp4k-01:1(config-mlt)#fa 
FA_server_vsp4k-01:1(config-mlt)#enable

 
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.