TitleHow to add ELRP alarms via Netsight Console
Objective
  • Ensure Netsight shows alarms when a loop is detected by ELRP.
Environment
  • Netsight Console
  • EXOS ALL
Procedure
  • Make sure ELRP is configured properly on the switch.
  • on Netsight, do the following
    • go to tools à Alarm/Event àAlarm Manager
    • click on New Alarm and give it a name (you can call it loop detected)
    • once you create a new alarm, make sure you highlight it and edit it as follows:
      1. set Alarm severity to Error
      2. check the “Enable Alarm” box.
      3. Choose the By Selected Trap radio button under Alarm Type. Click on Edit Traps.
      4. Find the trap called extremeElrpVlanLoopDetected (.1.3.6.1.4.1.1916.4.6.0.1), select it, click the green arrow then hit ok.
      5.  Hit apply.
Additional notes
  • You can change the alarm severity to any of the other options (e.g., info) 