How to delay link up of certain ports on boot in EXOS

« Go Back

Information

 
TitleHow to delay link up of certain ports on boot in EXOS
Objective
Delay the link up of certain ports to ensure uplinks are ready first
Environment
EXOS All
Procedure
Configure an autoexec.xsf script to disable ports, then re-enable them after a delay.

An example is below for port 3, with a three minute delay. It can be modified as needed.
 
### autoexec.xsf Script for automatic Link Up Delay 
 
# Set a regular script timeout
configure cli script timeout 600
enable cli scripting
 
create log entry "Disabling port 3"
disable port 3
 
# wait a few minutes for the switch fully to come up
create log entry "Waiting 3 minutes for switch to come up (Link Up Delay)"
set var temp $TCL(after [expr 3 * 60 * 1000])
create log entry "Waiting done"
 
create log entry "Enabling port 3"
enable port 3
 
disable cli scripting

 