Reset Search
 

 

Article

How to factory default an AP7502 when AP Discovery/Reset Tool is not an option.

« Go Back

Information

 
TitleHow to factory default an AP7502 when AP Discovery/Reset Tool is not an option.
Objective
How to factory default the AP-7502 without using the AP Discovery/Reset tool?
Environment
  • AP-7502
  • AP7502
  • AP-7502E
  • AP7502E
Procedure
RJ45 loop back connector will be required, which the following covers.
To make the RJ45 loop connector:

Cut the sheath on Orange-White wire (2) and Green wire (6) and twist them together.
Cut the sheath on Green-White wire (3) and Orange wire (1) and twist them together.

Using the RJ45 loop back connector (wires 1 and 3 and wires 2 and 6):

1.- Connect RJ45 loop back connector to port FE2.
2.- Power on the AP.
3.- Wait for 2 minutes (probably not necessary to wait 2 minutes, but seems to produce better results when waiting 2 minutes)
4.- Disconnect the RJ45 loop back connector, and power off the AP.
5.- Power on the AP again, without RJ45 loop back connector. In 2 minutes, the APs register MAC address should be in the visible on the switch.


 
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.