Procedure
  • identify the FM you need to reboot :
# show slot
Slots    Type                 Configured           State       Ports  Flags
-------------------------------------------------------------------------------
FM-1     BDXA-FM20T                                Operational    0   MB
FM-2     BDXA-FM20T                                Operational    0   MB
FM-3     BDXA-FM20T                                Operational    0   MB
FM-4     BDXA-FM20T                                Operational    0   MB
  • disable the Fm :
  • # disable slot FM-
      <slot>          Slot number
        "FM-1"  "FM-2"  "FM-3"  "FM-4"
     # disable slot FM-1
    check for FM :
# sh slot
Slots    Type                 Configured           State       Ports  Flags
-------------------------------------------------------------------------------
FM-1     BDXA-FM20T                                Down           0     D
  • Enable FM :
  • # enable slot FM-
      <slot>          Slot number
        "FM-1"  "FM-2"  "FM-3"  "FM-4"
    # enable slot FM-1
    check for booting of FM:
  • # sh slot
    Slots    Type                 Configured           State       Ports  Flags
    -------------------------------------------------------------------------------
    FM-1     BDXA-FM20T                                Booting        0
    FM-2     BDXA-FM20T                                Operational    0   MB
    FM-3     BDXA-FM20T                                Operational    0   MB
    FM-4     BDXA-FM20T                                Operational    0   MB


     