Reset Search
 

 

Article

Why Does "show system verbose" From ERS 5900 Contain More Power Supply Info Than ERS 4900?

« Go Back

Information

 
TitleWhy Does "show system verbose" From ERS 5900 Contain More Power Supply Info Than ERS 4900?
Question
Why does an ERS 5900 have more power supply information included in show system verbose output than ERS 4900 when both are running 7.6.2.019 release?

ERS 5900 release 7.6.2.019
5928GTS-uPWR#show system verbose
System Information:
Operation Mode: Stack, Unit # 1
Size Of Stack: 2
Base Unit: 1
MAC Address: 64-C3-54-8B-3C-01
PoE Module FW: 1.5.0.10
Reset Count: 22
Last Reset Type: Management Reset
Autotopology: Enabled
Base Unit Selection: Base unit using rear-panel switch
sysDescr: Ethernet Routing Switch 5928GTS-uPWR
HW:01 FW:7.5.0.2 SW:v7.6.2.019
sysObjectID: 1.3.6.1.4.1.45.3.81.5
sysUpTime: 0 days, 00:03:11
sysNtpTime: NTP not synchronized.
sysRtcTime: Sunday 2006/09/24 19:22:14
sysServices: 6
sysContact:
sysName:
sysLocation:
Stack sysAssetId:
Operational license: Base Software
Installed license: Base Software
Unit #1 (Base Unit):
Switch Model: 5928GTS-uPWR
Pluggable Port 25: (25) None
Pluggable Port 26: (26) None
Pluggable Port 27: (27) None
Pluggable Port 28: (28) None
MAC Address: 64-C3-54-8B-3C-00
PoE Module FW: 1.5.0.10
Hardware Version: 01
Firmware Version: 7.5.0.2
Firmware FLASH: 7.5.0.2
Software Version: v7.6.2.019
Software FLASH: v7.6.2.019
Serial Number: 16OL11400200
Manufacturing Date: 20160305
Power Supply 1:
Order Code AL1905A3F-E6
Order Coder Rev R01
Description AC-DC-56V1400W-F2B
Serial Number K636RG001YETZ700
Supplier Part Num Z700-013146-1
Model Revision REV.ET
Manufacturer ARTESYN
Power Supply 2:
Order Code AL1905A3F-E6
Order Coder Rev R01
Description AC-DC-56V1400W-F2B
Serial Number K636RE0054ETZ700
Supplier Part Num Z700-013146-1
Model Revision REV.ET
Manufacturer ARTESYN
Power Status : 1- OK 2- No Input Power
Fan #1 Status: Normal
Fan #2 Status: Normal
Fan #3 Status: Normal
Fan #4 Status: Normal
Unit sysAssetId:
Unit #2:
Switch Model: 5928GTS-uPWR
Pluggable Port 25: (25) None
Pluggable Port 26: (26) None
Pluggable Port 27: (27) None
Pluggable Port 28: (28) None
MAC Address: 64-C3-54-8B-30-00
PoE Module FW: 1.5.0.10
Hardware Version: 01
Firmware Version: 7.5.0.2
Firmware FLASH: 7.5.0.2
Software Version: v7.6.2.019
Software FLASH: v7.6.2.019
Serial Number: 16OL11400197
Manufacturing Date: 20160305
Power Supply 1:
Order Code AL1905A3F-E6
Order Coder Rev R01
Description AC-DC-56V1400W-F2B
Serial Number K636RG001KETZ700
Supplier Part Num Z700-013146-1
Model Revision REV.ET
Manufacturer ARTESYN
Power Supply 2:
Order Code AL1905A3F-E6
Order Coder Rev R01
Description AC-DC-56V1400W-F2B
Serial Number K636RE0021ETZ700
Supplier Part Num Z700-013146-1
Model Revision REV.ET
Manufacturer ARTESYN
Power Status : 1- OK 2- No Input Power
Fan #1 Status: Normal
Fan #2 Status: Normal
Fan #3 Status: Normal
Fan #4 Status: Normal
Unit sysAssetId:
5928GTS-uPWR#

ERS 4900 release 7.6.2.019
4950GTS-PWR+#show system verbose
System Information:
Operation Mode: Switch
MAC Address: C4-BE-D4-82-60-00
PoE Module FW: 1.5.0.11
Reset Count: 1064
Last Reset Type: Management Reset
Autotopology: Enabled
Base Unit Selection: Base unit using rear-panel switch
sysDescr: Ethernet Routing Switch 4950GTS-PWR+
HW:01 FW:7.5.0.2 SW:v7.6.2.019
sysObjectID: 1.3.6.1.4.1.45.3.82.4
sysUpTime: 0 days, 00:03:02
sysNtpTime: NTP not synchronized.
sysRtcTime: Friday 2009/01/16 01:30:04
sysServices: 6
sysContact:
sysName:
sysLocation:
Stack sysAssetId:
Operational license: Base Software
Installed license: Base Software
Unit #1:
Switch Model: 4950GTS-PWR+
Pluggable Port 49: (49) SX
Pluggable Port 50: (50) SX
PoE Module FW: 1.5.0.11
Hardware Version: 01
Firmware Version: 7.5.0.2
Firmware FLASH: 7.5.0.2
Software Version: v7.6.2.019
Software FLASH: v7.6.2.019
Serial Number: 16OL13600241
Manufacturing Date: 20160315
Power Supply 1: Unavailable
Power Supply 2: Unavailable
Power Status : 1- Not Present 2- OK
Fan #1 Status: Normal
Fan #2 Status: Normal
Fan #3 Status: Normal
Fan #4 Status: Normal
Unit sysAssetId:
4950GTS-PWR+#

 
Environment
  • ERS 4900
  • ERS 5900
  • Release 7.6.2.019
Answer
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255