Reset Search
 

 

Article

What is the correct port status for ports 1-42 on the VDX 2740 to show when "UP"?

« Go Back

Information

 
TitleWhat is the correct port status for ports 1-42 on the VDX 2740 to show when "UP"?
Question
What is the correct port status for ports 1-42 on the VDX 2740 when the ports are "UP", in the output from show interface status?
Environment
  • NOS
  • VDX 2740
Answer
Ports 1-42 are internal ports on the VDX 2740, connected to the chassis backplane, there is no slot for SFP's. As such, NOS displays the status as sfpabsent when issuing the show interface status command.
 
sw0# show interface status
--------------------------------------------------------------------------------
Port     Status    Mode  Speed Type Description
--------------------------------------------------------------------------------
Te 1/0/1 sfpAbsent Trunk 10G   10G  vmnic0
Te 1/0/2 sfpAbsent Trunk 10G   10G  vmnic1
Te 1/0/3 sfpAbsent Trunk 10G   10G  vmnic2
Te 1/0/4 sfpAbsent Trunk 10G   10G  vmnic3
Te 1/0/5 sfpAbsent Trunk 10G   10G  vmnic4

 
Additional notes
The show interface <INTERFACE> command will also display something similar.
 
sw0# show interface te 1/0/1
TenGigabitEthernet 1/0/1 is up, line protocol is up (connected)
Hardware is Ethernet, address is 0027.f8c9.0709
    Current address is 0027.f8c9.0709
Pluggable media not present

 