Question

Can NI-CER-2024F-RT-AC support up to 1.5 Million IPV4 routes?
If you are running BGPand need to full BGProuting table, then it is recommend that the CER support 1.5 million routes to allow for scale.

Environment
Answer

The CER with RT_Scale can support 1.5 Million routes but they shouldhave 0A chipset, so that the hardware can support that many routes.

CER's with FF chip set cannot support 1.5 Million routes even if they have RT_Scale License.

In such case , the only option is to change the hardware and request it with 0A chipset.


Steps to follow to increase the routes.


1. Check to see if Hardwarecan support (with0A chipset) in the hardware .

CER#hw pid slot back
CER# hw pid show

=== Manufacturing Information ====
Board Class : 0x21 (Metro 1Gx24 Copper)
Factory Assembly Part Number : 40-1000617-02
Chassis Type: METRO-HEAVY (0x40) [0A]<<<<<<<<<<Can support.
Factory Serial Number : L20336H00N
Chassis Serial Number : 1P2540H43R
Power Type: Unknown (ff)
Date of Manufacture : 9-24-2012
Bench Test Status : PASSED
Burn-in Test Status : PASSED
Manufacturing Deviation :
RMA Number :
OEM Vendor: None
OEM Vendor Serial Number:
OEM Vendor Part Number:
PCB Revision :
MFG Test :
SW License Id: GrHKJFjJIt


=== Manufacturing Information ====
Board Class : 0x21 (Metro 1Gx24 Copper)
Factory Assembly Part Number : 40-1000347-04
Chassis Type: METRO-HEAVY (0x40) [FF]<<<<<<<<<<<<Cannot support.
Factory Serial Number : L20528F011
Chassis Serial Number : K00538F071
Power Type: Unknown (ff)
Date of Manufacture : 7-23-2010
Bench Test Status : PASSED
Burn-in Test Status : PASSED
Manufacturing Deviation :
RMA Number :
OEM Vendor: None
OEM Vendor Serial Number:
OEM Vendor Part Number:
PCB Revision :
MFG Test : 051288
SW License Id: mFFKINhFMG

2. Need License: RT_SCALE.


3. Need to change the System-max value to support 1.5 Million routes in the CLI and do a reload to take effect.

Additional notes