TitleInformation not getting updated periodically for PSU,Odometer,Temperature and Fan
Question
Why Information not getting updated periodically for PSU,Odometer,Temperature and Fan for Black Diamond 8810 switch?
Environment
  • Black Diamond8810
  • EXOS15.3.5.2p1-7
Answer
Information not getting updated in the switch for the PSU odometer, temperature and fan.
In "show power" command out put odometer value is not getting updated in every 30 minutes Whereas In "debug hal show platform platforminfo" it is getting updated .

Execute command "show power" and "debug hal show platform platforminfo" and observe that the odometer,fan RPM and temperature is not getting updated  every 30 minutes.

The reason for  this is found to be a software bug. The CR#xos0066410 has been created already. For further information on this please contact GTAC for the fix availability in  the future. Anyway this is expected to release in another 2 weeks time from now.