Reset Search
 

 

Article

Summit switch Temperature "Overheat" behavior

« Go Back

Information

 
TitleSummit switch Temperature "Overheat" behavior
Question
  • Summit X670V-48t VIM4-40G4X module reporting temperature state "Warning" with following logs are generated:

09/12/2016 10:37:04.18 <Erro:DM.Error> Switch: plugin slot-A module temperature (50 C) is reaching maximum limit (60 Celsius). (X670V-48t, P/N: 800518-00-09, S/N: 1514N-40156, Rev: 9.0)
09/12/2016 10:24:04.18 <Noti:DM.Notice> No Environment warnings present.  Setting Environment LED color back to Green (normal)
09/12/2016 10:24:04.18 <Noti:DM.Notice> Switch: plugin slot-A module temperature (50 C) is back to operating range (15 to 50 Celsius). (X670V-48t, P/N: 800518-00-09, S/N: 1514N-40156, Rev: 9.0)
09/12/2016 10:08:38.84 <Info:vlan.msgs.portLinkStateUp> Port 41 link UP at speed 1 Gbps and full-duplex
09/12/2016 09:57:19.03 <Warn:DM.Warning> Environment warning reported.  Setting Environment LED color to Amber
09/12/2016 09:57:19.03 <Erro:DM.Error> Switch: plugin slot-A module temperature (50 C) is reaching maximum limit (60 Celsius). (X670V-48t, P/N: 800518-00-09, S/N: 1514N-40156, Rev: 9.0)
09/12/2016 09:52:38.75 <Info:vlan.msgs.portLinkStateUp> Port 38 link UP at speed 1 Gbps and full-duplex
09/09/2016 16:14:20.41 <Warn:DM.Warning> Environment warning reported.  Setting Environment LED color to Amber
09/09/2016 16:14:20.41 <Erro:DM.Error> Switch: plugin slot-A module temperature (50 C) is reaching maximum limit (60 Celsius). (X670V-48t, P/N: 800518-00-09, S/N: 1514N-40156, Rev: 9.0)
09/09/2016 15:50:14.70 <Warn:NetTools.SNTP.TxReqToSrvrFail> Failed to send SNTP request to server 192.168.10.201

  • ​As per the EXOS documentation "EXOS 21.1 User Guide" and "ExtremeSwitching and Summit Switches: Hardware Installation Guide for Switches Using ExtremeXOS 21.1", we could see the non-identical statements provided on two different documents when the switch status “Overheat”.
Environment
  • Summit x670V-48t VIM4-40G4X module
  • 15.6
Answer
  • Following is the consolidated information that we are planning to update on our future documentation, through CR# xos0066175

Content on EXOS user guide needs to be changed to:-
    -   On Summit family switches, if a switch runs outside the expected range, the switch logs an error message, generated trap, and one of the following actions is executed:

  1. If overheat condition happens on a slot of a SummitStack, then the reset/none option from “configure sys-recover-level” is used to perform appropriate action.

  2. If the device is an X430-8p then the device is shut down regardless of the recovery level and after reboot the user is presented with a prompt of whether or not to boot the switch .

  3. If the device is any standalone summit, other than X430-8p, then only a warning is logged and the switch continues to run with the system state as Overheat. And if the temperature further increases in overheat condition, after the operating temperature crosses a further higher temperature, the hardware resets the switch

Add following note on SummitFamily Hardware installation guide:
    -  Under Temperature topic:The X430-8P switch doesn't have the hardware capability to reset the switch so the switch will be rebooted by software and user intervention is required to boot the switch.

  • For further clarifications, please contact GTAC. 