Reset Search
 

 

Article

What are the "Erro:EDP.ProcPDUFail" log events mean? 

« Go Back

Information

 
TitleWhat are the "Erro:EDP.ProcPDUFail" log events mean? 
Question
What are the "Erro:EDP.ProcPDUFail" log events mean? 
 
10/18/2017 19:40:52.16 <Erro:EDP.ProcPDUFail> MM-A: pdu received on port 3:30 could not be processed, Checksum error
10/18/2017 17:49:06.57 <Erro:EDP.ProcPDUFail> MM-A: pdu received on port 3:32 could not be processed, Checksum error
10/18/2017 17:43:16.64 <Erro:EDP.ProcPDUFail> MM-A: pdu received on port 3:33 could not be processed, Checksum error
10/18/2017 12:42:02.01 <Erro:EDP.ProcPDUFail> MM-A: pdu received on port 3:28 could not be processed, Checksum error


 
Environment
  • All Extreme Exos switches
  • All Exos versions.
Answer
These error messages indicate that the switch has reported EDP checksum errors. This occurs when the switch receives corrupted EDP data on a port. This could be a physical layer issue or a problem with the switch.
If a peer switch has a parity error, transmitted PDUs might be corrupted.

How to check Parity error? 
Additional notes