Reset Search
 

 

Article

Why is my WiNG AP not getting adopted by the VX9000?

« Go Back

Information

 
TitleWhy is my WiNG AP not getting adopted by the VX9000?
Question
Why is my AP not getting adopted by the VX9000?
Environment
  • WiNG APs
  • VX9000
  • WiNG 5.x
  • CLI
  • SSH or Console (baud rate: 115200 or 19200)
Answer
In this situation the following conditions were met:
  1. Successful ping between the controller and AP and vice versa
  2. Mint Link was successfully established between both
Running the following command on the controller provided us with more details on this issue:
>en
#show adoption pending
The AP was listed as pending adoption and the reason was due to a missing VX appliance license. 
We confirmed this by running the following command:
#show lic
Installing the VX appliance license resolved issue and allowed the AP to properly adopt and pull the config. 

Related articles:
How to apply (add) any license key to a WiNG controller via the CLI
How to apply a WING VX appliance license key via the CLI
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255