Reset Search
 

 

Article

SNMPv3 Requests To Industrial Switches (ISW) Stop Working If NTP Is Enabled; usmStatsNotInTimeWindows

« Go Back

Information

 
TitleSNMPv3 Requests To Industrial Switches (ISW) Stop Working If NTP Is Enabled; usmStatsNotInTimeWindows
Symptoms
  • SNMPv3 requests stop receiving responses after NTP time sync occurs on the ISW switch.
  • Extreme Management Center can not discover or determine the status of the device via SNMPv3.
  • With NTP disabled SNMPv3 requests are responded to as expected.
Environment
  • Industrial Switch (ISW)
  • v01.01.02.0005
  • v01.01.02.0007
  • v1.1.2.5
Cause
Behavior is confirmed to be a bug and will be fixed in the release v01.01.02.0008. 
Resolution

For software release v01.01.02.0005 and 0007, disable NTP and reboot the switch to enact the change.
Additional notes
ISW switches managed by Extreme Management Center using SNMPv3 are impacted by the defect noted above.

A tcpdump from XMC will show the following during a device (re-)discover, resulting in a usmStatsNotInTimeWindows response:
07:06:10.298071 IP xmc.local.40640 > isw_switch_ip.snmp:  F=r U="" E= C="" GetRequest(14) 
07:06:10.578269 IP isw_switch_ip.snmp > xmc.local.40640:  F= U="" E=_d8_84_66_fd_e2_0d C="" Report(33)  S:snmpUsmMIB.usmMIBObjects.usmStats.usmStatsUnknownEngineIDs.0=22247
07:06:10.755359 IP xmc.local.40640 > isw_switch_ip.snmp:  F=apr U="snmpuser" [!scoped PDU]47_10_c3_29_11_88_d6_10_2c_57_3c_a2_11_47_16_05_a6_6d_31_7d_b3_0c_4e_15_20_87_c0_3d_af_d2_ed_8d_04_cd_8d_60_35_97_34_0d_e1_49_76_59_cb_2e_ce_04_0d_b5_40_61_7b_44_a0_b5_a3_f6_96_4a_b2_a8_21_fd_5c_3f_8a_12_87_d7_9f_9c
07:06:10.887926 IP isw_switch_ip.snmp > xmc.local.40640:  F=a U="snmpuser" E=_d8_84_66_fd_e2_0d C="" Report(34)  S:snmpUsmMIB.usmMIBObjects.usmStats.usmStatsNotInTimeWindows.0=66134