Reset Search
 

 

Article

System: Health Monitoring: FE Access failure detected on SFM

« Go Back

Information

 
TitleSystem: Health Monitoring: FE Access failure detected on SFM
Symptoms
  • User sees errors are generating in log:

System: Health Monitoring: FE Access failure detected on SFM 2/FE 1 Jan 1 15:36:03:A:
System: Health Monitoring: FE Access failure detected on SFM 2/FE.
Environment
  • NI 05.4.00
Cause
SerDes EPB-access operation was not written properly.
This can be caused by SerDes access while IPU/CMU is still in-reset.
This can be also caused by insufficient delay between two EPB-access operations, or general problem with ECI access.
Resolution
Powering off the moduleand then powering on will fix theissue, as this will reset/re-sync EPB process.

#show clock
#skip
#show log
#power-off snm 2
#<wait at least a minute>
#power-on snm 2
#<wait at least a 3-5 minutes>
#show log
#show tech-support


Loghealth messages should now cease. If not, RMA switch fabric module.
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.