Reset Search
 

 

Article

The 'show chassis' command displays invalid module with power usage for an empty slot.

« Go Back

Information

 
TitleThe 'show chassis' command displays invalid module with power usage for an empty slot.
Symptoms
  • The show chassis command displays invalid module with power usage for an empty slot.
Environment
  • NI 5.4.00d
Cause
The show chassis command was incorrectly reporting this information after a module had been inserted into the slot and removed.

This is a cosmetic bug. The power usage for the empty slot is displayed, but it is not considered in the calculation of the total power used by the LPs, so there is no functional impact from this display issue.

Note: When another module is inserted in the empty slot the show chassis command will display the correct power consumption value for the inserted module.
Resolution
Upgrade code to one of the following releases:
  • 5.4.00g and later patch releases
  • 5.6.00d and later patch releases
  • 5.7.00 and later patch releases
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.