Reset Search
 

 

Article

Switch Logging NVR FSH Flash Errors

« Go Back

Information

 
TitleSwitch Logging NVR FSH Flash Errors
Symptoms
  • Switch logging NVRAM errors in log file
Type Unit Time                          Idx  Src Message
---- ---- ----------------------------- ---- --- -------
C    3    2018-05-15 23:22:08 GMT-04:00 43   NVR FSH - Error: Failed to erase flash address 848a0000 located in the Auxiliary Config
C    3    2018-05-15 23:23:19 GMT-04:00 44   NVR FSH - Error: Failed to erase flash address 840c0000 located in the Config-1
C    3    2018-05-15 23:28:25 GMT-04:00 50   NVR FSH - Error: Failed to erase flash address 84ca0000 located in the Audit Region
C    3    2018-05-15 23:28:49 GMT-04:00 51   NVR FSH - Error: Failed to erase flash address 84ce0000 located in the MCFG Block
C    3    2018-05-15 23:28:51 GMT-04:00 52   NVR FSH - Error: Failed to erase flash address 84d00000 located in the Backup MCFG Block
S    3    2018-05-15 23:29:18 GMT-04:00 57   NVR Audit commit failed (cannot write flash sector(s))
  • ​Cannot save configuration
ERS#save config 
% Could not copy to nvram

ERS#copy config nvram 
% Could not copy to nvram
  • 100,000 minimum number of guaranteed writes is exceeded on NBU (Non-Base Unit)
ERS#show flash history unit 2
----------------------------------------------------------------------------
FLASH Write History Unit 2:
----------------------------------------------------------------------------
Section            Number of writes
----------------------------------------------------------------------------
Diagnostics Image:       2
Agent Image:           5
Config Area 1:           197021
Config Area 2:           0
Auxiliary Config Area:       197021
MCFG Block :           197025
Audit log Area :       1491
---------------------------------------------------------------------------
* Number of minimum guaranteed writes: 100 000
---------------------------------------------------------------------------
  • Only affects NBU switches in stack
  • Reset stack and errors continue
Environment
  • ERS 4900/5900 releases 7.2.x, 7.3.x and 7.4.x
  • ERS 4800 release 5.10.x
Cause
  • Software defect ERS495900-4849 (ERS 4900/5900)
  • Software defect ERS454800-2791 (ERS 4800)
Resolution
Additional notes
Issue can be avoided by addressing either of the following options prior to flash failure when on affected versions of code:
  • Disable auto-save
  • Access switch periodically to ensure that at least one read/write user account remains active


 

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.