Reset Search
 

 

Article

Link State Tracking ports cannot be MLT members

« Go Back

Information

 
TitleLink State Tracking ports cannot be MLT members
Symptoms
  • In Enterprise Device Manager (EDM), select Multi Link Trunk (MLT) and insert, add ports x/x,x/x, apply,  only one port will be in the MLT.
  • CLI does not give the error and allows port members to be associated with the MLT.
mlt 1 enable
mlt 1 member x/x-x/x
mlt 1 encapsulation dot1q
  • Issue noticed in sw 7.0
  • Possible errors displayed
"Link State Tracking ports cannot be MLT members"
"unkown error"
Environment
  • VOSS
  • Software 7.0
Cause
  • Software Inconsistency when adding disabled port to link-state group and enabling it afterwards
Resolution
  • Upgrade to software 7.1
  • Issue is not seen when using CLI
Additional notes
VOSS-10202
 

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255