Reset Search
 

 

Article

Virtual Switch Platform (VSP) Power glitch leaves Ethernet Switch Module (ESM) physical interfaces (PHY(s)) in bad state ("Invalid port")

« Go Back

Information

 
TitleVirtual Switch Platform (VSP) Power glitch leaves Ethernet Switch Module (ESM) physical interfaces (PHY(s)) in bad state ("Invalid port")
Symptoms
  • Site power hit causes VSP to fail
  • Ports status down
  • system logs shows messages similar to below
Pollux local0.err ssio: *** No children 
Pollux local0.err ssio: cb_sw_l3_create_l3_intf (803): Invalid parameter
Pollux local0.err ssio: SPBOIP l3 intf creation failed 
Pollux local0.err ssio: lcdMdaCardInit: calling eventCardInsert for slot=1, pimType=30
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 9, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 10, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 11, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 12, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 13, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 14, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 15, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 16, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 17, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 18, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 19, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 20, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 21, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 22, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 23, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: cb_sw_port_set_macsec_mtu: port 24, set mtu(1982) failed, rv=-18, Invalid port
Pollux local0.err ssio: MDA Slot 1: 8424GT (8) 
Pollux local0.err ssio: MDA Slot 2: 8424GS (7) 
Pollux local0.err ssio: MDA Slot 3: None (0) 
Pollux local0.err ssio: MDA Slot 4: None (0) 
Pollux local0.err ssio: lcdMdaCardInit: calling eventCardInsert for slot=2, pimType=25
Pollux local0.err ssio: MDA Slot 1: 8424GT (8) 
Pollux local0.err ssio: MDA Slot 2: 8424GS (7) 
Pollux local0.err ssio: MDA Slot 3: None (0) 
Pollux local0.err ssio: MDA Slot 4: None (0)

 
Environment
  • VSP
  • Software version 5.1.1.5
Cause
  • A brief power glitch on the Avalanche chassis can result in the ESM PHY(s) on the card entering a wedged state
  • This is due to the loss of 1V power without the corresponding loss of 12V power
  • In this state the CPU complex programmable logic device (CPLD) stays up and the PHYs on the ESM are keep out of reset.   
Resolution
Upgrade software to version 6.1.5
 
Additional notes
Added correct power cycling of ESMs on normal soft reset to recover from power glitches