MPLS process ends unexpectedly with signal 11 while checking the status of LSP cross connect.

« Go Back

Information

 
TitleMPLS process ends unexpectedly with signal 11 while checking the status of LSP cross connect.
Symptoms
MPLS process ends unexpectedly with signal 11 while checking the status of LSP cross connect.
Environment
  • EXOS 16.2 and higher
  • MPLS 
Cause
The issue is documented and fixed under CR xos0071932.
Resolution
To avoid the issue it is needed to upgrade to latest patch of one of the following EXOS releases that contains CR xos0071932:
  • EXOS 22.5.1 (Released)
  • EXOS 16.2.5 (Released)