Can't find what you need?


• Ask the Community
• Create a Case
Reset Search
 

 

Article

Base Unit Exception In Stack Of (2) Switches Before Stack Broke and Loss Of Ping To Mgmt Address

« Go Back

Information

 
TitleBase Unit Exception In Stack Of (2) Switches Before Stack Broke and Loss Of Ping To Mgmt Address
Symptoms
  • Stack of (2) switches stopped responding to pings
  • Traffic still forwarded
  • Visual inspection confirmed no longer operating in stack mode
  • Former base unit (when in stack) had exception logged approx 1 hour before ping loss was noted
Last Saved Exception - Stand-Alone
--------------------------------------

bld version: 5.11.2.13 time: (19/Mar/18 09:18:41) view: (productio)
Exception time: 25/AUG/19 22:05:12
sysUpTime: 116 days, 08:38:36
Registers:

R00 R01 R02 R03 R04 R05 R06 R07
01516428 06b9cbf0 015ba1d8 00000000 00003032 00000003 00000000 4d61696e
R08 R09 R10 R11 R12 R13 R14 R15
00000000 00000001 00000001 00000000 ffffffff 0259f1c8 017ed610 017ed59c
R16 R17 R18 R19 R20 R21 R22 R23
017ed53c 017ed55c 017ed568 017ed548 017ed52c 017ed56c 017ed538 06b9cd38
R24 R25 R26 R27 R28 R29 R30 R31
00000000 00000000 00000000 00000000 00000000 00000000 0000b032 0a215c70

LR 0x01516438, CTR 0x01488cb0, MSR 0x0000b032, CR 0x24000444, XER 0x00000000

Exception type: Assert
Task Name "tCDTMain"
KrnlSt 0, IntCnt 0, TskLckCnt 0, DAR 0x00000000, PC 0x015992d4, SP 0x06b9cbf0

Exception Stack Trace
+ PC 0x015992d4
+ PC 0x000138b8
+ PC 0x003066c0
+ PC 0x005615e8
+ PC 0x00381fa0
+ PC 0x00382e30
+ PC 0x006a55a0
+ PC 0x00447b80
+ PC 0x005fd70c
+ PC 0x005e7160
+ PC 0x000d4024
+ PC 0xeeeeeeee
= Total 268 Bytes =
Environment
  • ERS 4850GTS-PWR+
  • Release 5.11.2.013
Cause
Software defect ERS454800-3095
Resolution
Resolved in 5.12.5 release
Additional notes