Reset Search
 

 

Article

S-Series Module Resets

« Go Back

Information

 
TitleS-Series Module Resets
Symptoms
  • Board reset
  • Core written
  • Logging buffer
<165>Nov 26 14:24:59 192.1687.50.11 System[6]The board in slot 4 of the chassis is not operational.
<165>Nov 26 14:24:59 192.168.50.11 Router[6]Router failover started time <165>Nov 26 14:35:36 10.137.50.11 Router[6]Router failover completed
<165>Nov 26 15:02:19 192.168.50.11 System[6]The board in slot 4 of the chassis is operational.
  • Show support Message log shows file system check error
Message 4/8 Shutdown 08.62.04.0002 11/26/2018 14:53:13
Initiated - Reset

Shutdown process is starting.

==============================================================================
Message 5/8 Fatal Error 08.62.04.0002 11/26/2018 14:53:13

ERROR: file system check
==============================================================================
Message 6/8 Syslog Message 08.62.04.0002 11/26/2018 14:53:10
<3>System[4]Flash volume /flash2 was repaired (1 passes). File system da ta may have been lost.
==============================================================================
Message 7/8 Syslog Message 08.62.04.0002 11/26/2018 14:53:10
<3>System[4]Flash volume /flash1 was repaired (1 passes). File system da ta may have been lost.
==============================================================================
Message 8/8 Informational 08.62.04.0002 11/26/2018 14:53:07

Device was last fully operational in user mode: 28 minutes, 12 seconds a
go. Last reset caused by: power loss.debug(dbg)<slot4>()->debug(dbg)<slot6>()->
Environment
  • S-Series
  • Allfirmaware
Cause
Likely hardware failure
Resolution
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.