A4-Series Shows Installed and Operating for Unused PS2-RPS source

« Go Back

Information

 
TitleA4-Series Shows Installed and Operating for Unused PS2-RPS source
Symptoms
Switch shows Power supply installed and operating when slot is empty
A4H124-48-198.177(su)->show system
System contact: jparker@extremenetworks.com System location: Jasons Labratory
System name: A4H124-48


Switch 1
--------
PS1-Status PS2-Status
---------- ----------
Installed and Operating Installed and Operating

Fan1-Status Fan2-Status
----------- -----------
Installed and Operating Installed and Operating

Temp-Alarm
-----------
off
Thermal Threshold: 62%
Temp alarm max threshold: 100%
Temp alarm trap: disabled
Temp alarm syslog: disabled
Uptime d,h:m:s Logout
-------------- -------
33,2:30:47 0 min


 
Environment
 
  • A4H124-48 only
  • Any Firmware
Cause
This is a display issue 
Resolution
The issue will not be addressed and this is now documented in the released notes as Functioning as designed. 
The only product affected is the A4H124-48 non PoE
RMA will not address the issue
Firmware will not address the issue
The redundant power connecting should work without any issues


 