TitleAdd had mixed results. 1 units succeeded, 1 failed
Symptoms
Switch is continually logging the messages below:
<Warn:Kern.IPv4Adj.Warning> Slot-<slot#>: vrId 2 adj <Hex_IP_Address> Add had mixed results. 1 units succeeded, 1 failed (rc Operation failed) flags 0x18200
<Warn:Kern.IPv4Adj.Warning> Slot-<slot#>: vrId 2 adj <Hex_IP_Address> Add had mixed results. 1 units succeeded, 1 failed (rc Operation failed) flags 0x18200
<Warn:Kern.IPv4Adj.Warning> Slot-<slot#>: vrId 2 adj <Hex_IP_Address> Add had mixed results. 1 units succeeded, 1 failed (rc Operation failed) flags 0x18200
<Warn:Kern.IPv4Adj.Warning> Slot-<slot#>: vrId 2 adj <Hex_IP_Address> Add had mixed results. 1 units succeeded, 1 failed (rc Operation failed) flags 0x18200

 
Environment
  • EXOS 15.3.1.4-patch1-47
  • BlackDiamond X8
  • BDXA-40G12X
Cause
This indicates that the ARP entry for the specified IP address was not able to be installed into hardware on one switch fabric chip in the slot specified.
Resolution
A reseat of the specified module may resolve this issue.