Reset Search
 

 

Article

Alarm for extremePsuPowerStatus trap is not trigger for X690-48x-2q-4c

« Go Back

Information

 
TitleAlarm for extremePsuPowerStatus trap is not trigger for X690-48x-2q-4c
Symptoms
Removing one of the PSU or disconnecting the cable does not trigger Power Supply Failed alarm
Environment
  • Extreme Management Center
  • X690-48x-2q-4c
  • ONIE
Cause
Loopback address is used to add the switch in Extreme Management center but the switch sends traps/informs using different source address.

 
Resolution
1. Remove and re-add the switch using the IP which it uses to sends the trap/informs and reconfigure the trap receiver from Extreme Management Center.
            Netsight: How to configure a summit switch to send a SNMP v3 trap to Netsight, and have Netsight correctly log the trap for that switch
2. Modify the switch config to send the traps/inform using the loopback IP address.
   
configure snmpv3 add target-addr "Trap receiver" param "Trap_Username" ipaddress <XMC IP> from <LoopbackIP of the switch> vr vr-default

 