Reset Search
 

 

Article

Black Diamond logs the Temperature (50 C) is reaching maximum limit (60 Celsius)

« Go Back

Information

 
TitleBlack Diamond logs the Temperature (50 C) is reaching maximum limit (60 Celsius)
Symptoms
  • Black Diamond logs the Temperature (50 C) is reaching maximum limit (60 Celsius)
Environment
  • Black Diamond 
  • EXOS
Cause
accumulation of dust  preventing required airflow to cool the switch 
Resolution
check the airflow and clean fan tray  if necessary
 
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255