C3 Switch keeps resetting with Osapi.c(3110) error

« Go Back

Information

 
TitleC3 Switch keeps resetting with Osapi.c(3110) error
Symptoms
Switch keeps resetting at random times. The current.log file displays the following error during each reset:
<160>Jul 25 23:48:26 172.18.100.129-1 SIM[144182208]: osapi.c(3110) 176 %% Error(0x6165c6)
Environment
  • C-Series
  • Securestack
  • Firmware 06.61.07.xx and earlier
Cause
  • Securestacks perform an automatic save of the configuration.
  • Firmware issue allocated unnecessary memory every time the configuration was automatically saved.
Resolution
Upgrade to firmware 06.61.08.xx or later.
Additional notes
Release note entry in 06.61.08.xx code:
17478 Corrected an issue memory utilization associated with saving configuration files. This issue could result in memory exhaustion resulting in a reset. 

 