Reset Search
 

 

Article

CDP from WMware ESXi not shown as a neighbour on B5 switch

« Go Back

Information

 
TitleCDP from WMware ESXi not shown as a neighbour on B5 switch
Symptoms
CDP neighbour information is not learnt
 
Environment
  • Securestack
  • B5 Series
  • Ingress filtering feature enabled on the port
  • PVID does not egress on the same port
  • Firmware 6.81.05.0003
  • VMware ESXi
Cause
Firmware issue with the specific configuration
Resolution
Fixed in GA release 6.81.08.0005
As a workaround set the PVID to egress the port