TitleEthernet OAM does not come up on Onie-based platforms
Symptoms
Ethernet OAM Connectivity Fault Management does not come up on Onie-based platforms
Environment
Onie based (X465, X590, X690, and X870) switch running EXOS earlier than 30.3
Cause
Ethernet OAM packets were being lifted to the CPU of the switch, as expected, but were not forwarded to the OAM process. This prevented OAM from coming up.
Resolution
This issue is resolved in EXOS 30.3.1 and later versions of code.