Reset Search
 

 

Article

FDB is not check-pointed correctly with W-MLAG configuration.

« Go Back

Information

 
TitleFDB is not check-pointed correctly with W-MLAG configuration.
Symptoms
With W-MLAG configuration, when data vlan has “MLAG enabled ports as untagged and ISC ports as tagged” then FDB's are not check-pointed correctly to the peer.
Environment
  • EXOS 16.1 and higher
  • MLAG
Cause
The issue is documented under CR xos0073394.
Resolution
Please track the CR xos0073394 to know the version of EXOS the fix is available and upgrade the Devices. 
Workaround: add ISC ports as untagged in MLAG Data vlan to resolve the issue.
 