Fans failed error on X440-24t even if fans are not rotating on purpose

« Go Back

Information

 
TitleFans failed error on X440-24t even if fans are not rotating on purpose
Symptoms
X440-24t-10G[34].1 # show fans 

FanTray information:
 State:                  Operational
 NumFan:                 2
 Fan-1:                  Failed at 0 RPM
 Fan-2:                  Failed at 0 RPM
X440-24t-10G[34].2 # show temperature 
Field Replaceable Units               Temp (C)   Status   Min  Normal   Max
---------------------------------------------------------------------------
Switch         : X440-24t-10G           28.50    Normal   -10    0-48  55
X440-24t-10G[34].3 #
Environment
  • Summit X440
  • EXOS 16.1
Cause
Fan speed of “0” RPM is expected in X440-24t switches of hardware revision greater than or equal to 5.0. Fan will rotate only when the temperature exceeds normal value “0-48”. Due to a software bug, EXOS incorrectly interprets the fan speed of 0 RPM as a failure.
 
Resolution
The fix for this issue is implemented in 16.2.4.5-patch1-2 as CRs xos0066179 and xos0069740.
To avoid the issue please upgrade to 16.2.4.5-patch1-2 or higher releases.

If temperature of the switch is higher then +48° C and "show fans" says that fans are failed then please contact the GTAC for further assistance.
Additional notes
For other issues with fans on X440 platforms please refer to KB article Summit X440 Fan Failure