TitleISW : Industrial Series Switch loses config when Banner MOTD is configured
Symptoms
Config is defaulted when reloading after configuring a Banner MOTD using the following format
 
testswitch(config)# banner motd c 
Enter TEXT message.  End with the character '^'.
###Test### c

after using that config and copying running-config to startup-config, then reload cold the switch goes back to default config.
 
Environment
  • ISW Industrial Series Switch
  • Firmware Version: 01.01.02.0004
  • ISW 8GbP, 4-SFP, PoE Switch
  • Banner motd feature
Cause
firmware issue
Resolution
under investigation 
please open a case with GTAC for estimate of fix
How to contact Extreme Networks Global Technical Assistance Center (GTAC)

Workaround:

Configure using the preferred format and the issue does not happen
 
testswitch(config)# banner c ###TEST### c motd

 