In NOS 6.0.2ha the command "show process cpu rbridge-id all history" returns "command not supported on this platform" even though it worked just fine in NOS 5.0.2b.

« Go Back

Information

 
TitleIn NOS 6.0.2ha the command "show process cpu rbridge-id all history" returns "command not supported on this platform" even though it worked just fine in NOS 5.0.2b.
Symptoms
In NOS 6.0.2ha the command "show process cpu rbridge-id all history" returns "command not supported on this platform" even though it worked just fine in NOS 5.0.2b.
Environment
  • VDX6740
  • NOS 6.0.2h, NOS 6.0.2ha, and other later versions with the fixes for DEFECT 000659778 and 000659781
Cause
The recording of some historical information was deprecated in NOS 6.0.2h as part of changes introduced to reduce the workload on the CF drive and prevent CF failure.
Resolution
This is expected behavior for software with changes implemented to prevent CF failure.

For more information please refer to FN-2018-419 - Flash Card Failures on Certain VDX Model Switches.