SecureStack inlinepower Oper status is "Other Fault"

« Go Back

Information

 
TitleSecureStack inlinepower Oper status is "Other Fault"
Symptoms
  • Inline power Oper status is "Other Fault"
  • Ports do not provide PoE
support->show port inlinepower


Port     Type                 Admin   Oper                Priority   Class   Power(W)
-------  -----                ------  -----------------   --------   -----   --------
ge.1.1                        auto    Other Fault         Low        0                 
ge.1.2                        auto    Other Fault         Low        0                 
ge.1.3                        auto    Other Fault         Low        0                 
ge.1.4                        auto    Other Fault         Low        0                 
ge.1.5                        auto    Other Fault         Low        0

 
Environment
  • SecureStack
  • A-Series
  • B-Series
  • C-Series
  • All firmware
Cause
Could be possible hardware failure or an issue with the PoE configuration on the port.
Resolution
  • First, try to adjust the port configuration using this command set port inlinepower port-string admin auto capability 802.3af and if this does not solve the issue then create RMA for hardware failure. 
  • Submit an RMA through our Support Portal or contact the GTAC for immediate technical assistance

To Learn more go to: 
Submit an RMA Case on the Extreme Portal