Reset Search
 

 

Article

Issues with PoE+ after upgrading from 16.2.5.4patch1-10

« Go Back

Information

 
TitleIssues with PoE+ after upgrading from 16.2.5.4patch1-10
Symptoms
After upgrading to firmware greater than 16.2.5.4patch1-11 on a x440 or x460 generation 1 switch, some  PoE+ devices can no longer be powered on.

This is due to a code change involving the way the inrush settings are handled between patch1-10 and patch1-11.


 
Environment
  • EXOS version 16.2.5.4
  • x440
  • x460
Cause
Resolution
Issue is not present in 16.2.5.4patch1-10.  Downgrade to that version until bug has been addressed.
A CR has been created to track this issue:  xos0076637.
Additional notes
Inrush current is the instantaneous high input current drawn by a device during the power up procedure.  

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255