Can't find what you need?


• Ask the Community
• Create a Case
Reset Search
 

 

Article

K-Series line-card shutting down with Fuji MAC MAIN intr error messages in syslog and debug message logs

« Go Back

Information

 
TitleK-Series line-card shutting down with Fuji MAC MAIN intr error messages in syslog and debug message logs
Symptoms
K-Series line-card shutting down with Fuji MAC MAIN intr messages in syslog and debug message logs
    <3>System[11]Halting the line card in slot 1 ( KT2006-0224 pn 9404352, 
    sn XXXXXXXXXXXX ) due to a detected failure
    <3>Fuji[11.tLcIntr]Switch Chip 0 (Slot 1 Line Card) detected fatal condition.
    <3>Fuji[11.tLcIntr]Fuji MAC MAIN intr: Fuji=0, Adr=0, Reg=0x00000010
Messages may change depending on firmware:
    <3>System[11]Restarting the line card in slot 2 ( KG2001-0224 pn 9404353
    , sn XXXXXXXXXXXX ) due to a detected failure
    <3>Fuji[11.tLcIntr]Switch Chip 2 (Slot 2 Line Card) detected fatal condition.
    <3>Fuji[11.tLcIntr]Fuji MAC MAIN intr: Fuji=2, Adr=0, Reg=0x00000010

 
Environment
  • K-Series
  • KT2006-0224
  • KG2001-0224
  • All firmware versions
Cause
Hardware failure with Fuji Chip
Resolution
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255