TitleK10 Spontaneously Rebooting After Three -Five Minutes
Symptoms
  • Chassis continues to reset every 5 minutes
  • Removal of failed blade stabilizes chassis
  • Log messages seen in "show support"
  •  
  • Message 74/234 Syslog Message 08.62.02.0022 04/02/2017 09:40:51
    <3>System[11]Restarting the line card in slot 7 ( KT2006-0224 pn 9404352
    , sn 12490124685H ) due to a detected failure
    
    ==============================================================================
    Message 75/234 Syslog Message 08.62.02.0022 04/02/2017 09:40:50
    <3>NIM[11.tNismProc]Line card in slot 7 ( KT2006-0224 pn 9404352, sn 12
    490124685H ) initialization failure... Failed to configure switch chip.
    (0xffffffff,0x00000000)
    
    ==============================================================================
    Message 76/234 Syslog Message 08.62.02.0022 04/02/2017 09:40:50
    <3>Fuji[11.tNismProc]fujiSpauiLinkStatusCheck: Fuji 12 SPAUI link check
    failed.
    
    ==============================================================================
    Message 77/234 Syslog Message 08.62.02.0022 04/02/2017 09:40:50
    <3>Fuji[11.tFujiAge]fujiAgeTransId: Fuji=12, adr=0x60900038, transId=0,
    seqNum=1 write access timeout
    
    ==============================================================================
    Message 78/234 Syslog Message 08.62.02.0022 04/02/2017 09:40:31
    <3>Fuji[11.tNismProc]fujiInit: Fuji 12 Stonehenge/Hammer training failed
    .
    
    ==============================================================================
    Message 79/234 Syslog Message 08.62.02.0022 04/02/2017 09:40:31
    <3>Fuji[11.tNismProc]fujiStonehengeHammerInterfaceTraining: Calibration
    timed out for Slave Id 6.

 
Environment
  • K-Series
  • Firmware 08.62.02.0022
Cause
Replace Bad  Hardware
Resolution
This message is a hardware fault

If seeing symptoms described in this article then the next step is to submit an RMA.
Action:Submit an RMA Case on the Extreme Portal