TitleLLDP information in SNMP is not correct
Symptoms
When EXOS is queried with SNMP for LLDP information, some information like lldpRemSysCapSupported  is wrongly formatted.
Environment
  • EXOS 
  • LLDP
  • SNMP
Cause
This is caused by calculating the wrong SYNTAX bits, EXOS is starting from LSB instead of MSB. This is known as CR xos0065946.
As a result of this an AP connected to an EXOS switch is seen as a router by Netsight for example.
Resolution
Upgrade to a fixed EXOS version when available.
EXOS 16.2.2, February 2016 patch
EXOS 21.1.3
EXOS 22.2.1

LLDP tables that are wrong calculated are: