TitleMSM gets stuck in present state after failover
Symptoms
Backup MSM fails to sync during bootup in fully loaded chassis with ACLs cfg'd
Environment
  • All Black Diamond
  • All EXOS
Cause
When a chassis has more number of ACL policies configured, during MSM bootup after failover, it takes more time for the ACL's to get synced. Until then, MSM stays in present state. 
Resolution
CR# xos0063552 has been created to track this issue and following releases has fix for this CR:
  • 21.1.1.2
  • 16.2
  • 15.6.4.2-patch1-6
  • 15.7.3.1-patch1-7
  • 16.1.3.6-patch1-2
  • 15.3.5.2-patch1-11