Can't find what you need?


• Ask the Community
• Create a Case
Reset Search
 

 

Article

SecureStack and G3 units with 'i2c errors exceeded threshold' message

« Go Back

Information

 
TitleSecureStack and G3 units with 'i2c errors exceeded threshold' message
Symptoms
Error message 'i2c errors exceeded threshold' which may be followed by a reset
Environment
  • SecureStack B3-Series
  • SecureStack C3-Series
  • G3-Series
  • Firmware 6.61.13 and below
Cause
i2c bus error
Resolution
Firmware upgrade to 6.61.18.0001 or higher
Additional notes
The C5 and B5 Series have the same fix in 6.81.01

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255