Reset Search
 

 

Article

NetSight Notification error Fusion IPC is invalid

« Go Back

Information

 
TitleNetSight Notification error Fusion IPC is invalid
Symptoms
  • Notification error in server.log
  • ERROR [com.enterasys.netsight.server.notification.NotifyActionEngine] Notification: Fusion IPC is invalid: The Inprocess action does not contain a valid class name: "com.enterasys.fusion.common.NetSightNotificationService".
Environment
  • NetSight
  • Console
  • NAC Manager
  • OF_Connect
  • NetSight Upgrade from 5.1.x to 6.1.x
Cause
NetSight server upgraded from 5.1 to 6.1 but OF_Connect was not re-installed with correct version.
Resolution
1.  Start NAC Manager.
2.  Click Tools > Management and Configuration > Notifications.
3.  Uncheck the box next to Fusion IPC.
4.  Click on Close.
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255