ONMD-1005 Feature Mismatch: ETS unmatch was logged multiple times in the past but is no longer appearing.

« Go Back

Information

 
TitleONMD-1005 Feature Mismatch: ETS unmatch was logged multiple times in the past but is no longer appearing.
Symptoms
The raslog message ONMD-1005 Feature Mismatch: ETS unmatch was logged multiple times in the past but is no longer appearing.
Environment
  • VDX6740
  • NOS 7.0.1c1
  • 40Gbps interface used for non-ISL link
  • Connected to a Cisco Nexus7706 N77-F324FQ-25 over 40Gbps
Cause
The cause of the issue is most likely a discrepancy between DCBX-related LLDP settings on each end.
Resolution
If the message is no longer appearing, the issue has already been resolved. If no settings changes are recorded on the VDX side, settings must have been changed on the Cisco side. No further action is required.