Reset Search
 

 

Article

Only 7 ports are coming up out of 8 ports on G8Xc Module.

« Go Back

Information

 
TitleOnly 7 ports are coming up out of 8 ports on G8Xc Module.
Symptoms
  • Only 7 ports are coming up out of 8 ports on G8Xc Module when all ports are inserted with BASE-T tri-optics.
  • Issue did not appear when all ports are connected with SFP+ optics or mixed (BASE-T and SFP+/SPF).
Environment
  • Black Diamond 8806, 8900-MSM128, G8Xc. 
  • EXOS version 16.2.4.5-patch1-3, EXOS 15.5.4.2.
  • BASE-T tri-optics.
Cause
Resolution
This issue is address in CR xos0070438.

Workaround: 

To bring up inactive ports, use different model of the optics.