"Operation draining timed out" error message thrown while saving the configuration in switch.

« Go Back

Information

 
Title"Operation draining timed out" error message thrown while saving the configuration in switch.
Symptoms
  • Receive "Operation draining timed out" when trying to save the configuration or running "show configuration"
  • Cfgmgr is not responding to EMS
  • Fetch inline-power from master node.  No other nodes responding to request.
Environment
Summit Stack
EXOS 15.6.4
PoE
Cfgmgr
Cause
Master node was trying to fetch inline-power info from all the PoE slots and did not get response from some slots which makes the switch wait for infinite time instead of cancelling the request.
Resolution
CR # xos0064575 will address this.  Fixed in 22.1, 21.1.2.11, 16.2.2.1, 16.1.3.6-patch-1-10
Additional notes
"Operation draining timed out" message can occur for numerous reasons but generally occurs when some type of querying is going on causing EMS process to become busy.  This CR does not apply in the following scenarios:

1) If recommended code fix does not resolve issue this is not the same problem
2) If using non-poe capable switches. 

If any of the above apply, please open a case with GTAC to explore root cause further. 