TitlePeer down log message is not generated when mlag is configured with alternate path
Symptoms
When MLAG is configured with alternate path and ISC link goes down, Peer down log message is not generated

Topology:
 
SW1 (port 1) ---- (port 1) SW2 

both switches's mgmt IP is configured / used for MLAG altenate-ip via VR-MGMT 
Environment
  • EXOS 21.1.1.4
Cause
This is caused by CR xos0066323.
 
Resolution
Upgrade to an EXOS version that includes the fix for this issue.
  • EXOS 22.2.1
  • EXOS 21.1.3 which it is targeted in March 2017 time frame 