Can't find what you need?


• Ask the Community
• Create a Case
Reset Search
 

 

Article

Potential ISL between VDX6740 and VDX6940 recognized as ISL on the VDX6940 end not at the VDX6740 end

« Go Back

Information

 
TitlePotential ISL between VDX6740 and VDX6940 recognized as ISL on the VDX6940 end not at the VDX6740 end
Symptoms
A potential ISL link between a VDX6740 and VDX6940 is recognized as an ISL on the VDX6940 end of the link but not at the VDX6740 end of the link.
Environment
  • VDX6740
  • VDX6940
  • Logical chassis VCS
Cause
This issue can be caused by an ASIC lockup condition on the VDX6940 end of the link. For further information see FN-2018-424, VDX 6940 ASIC Interrupt Errors.
Resolution
This issue can be resolved by reloading the VDX6940.
Additional notes

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255