TitlePower Usage of external PSU of a X440G2 is 35483.47
Symptoms
When X440G2 platform connected with the external power supply , the show power output shows the junk value of power usage and that is not possible. 
On connecting the external power supply it wrongly detects the power usage for the external PSU:
X440G2-48t-10G4.7 # show power

PowerSupply 1 information:
State             : Powered On
PartInfo          : Internal Power Supply

PowerSupply 2 information:
State             : Powered On
PartInfo          : External Power Supply
Input             : 400.06 V AC
Output 1          : 40.00 V, 204.03 A   (12V/300W Max)
Power Usage       : 35483.47 W
Airflow Direction : N/A
Environment
  • X440G2
  • EXOS 21.1.1
Cause
This is wrong behavior because power monitoring for the X440G2 platform is not supported.
Resolution
CR# xos0072030​ will fix this issue