Reset Search
 

 

Article

Repeated Reboot of K10 Fabric Blade with "Fuji EDF FIFO" Error

« Go Back

Information

 
TitleRepeated Reboot of K10 Fabric Blade with "Fuji EDF FIFO" Error
Symptoms
Repeated reboots of K10 Blade
Error Message seen in logs:
<0>Fuji[11.tFabDevInt]Switch Chip 21 (Slot 11 Fabric Card) detected fatal condition. ( 0x00e54790 0x014d32d0 0x014cd088 0x0043744c 0x004621a8 0x016e0b64 0xeeeeeeee )
<3>Fuji[11.tFabDevInt]Fuji EDF FIFO intr: Fuji=21, Adr=2, Reg=0x80000000
Environment
  • K-Series
  • Firmware 08.42.03.0006
Cause
Failed Fabric Module 
Resolution
This message is a hardware fault.

If seeing symptoms described in this article then the next step is to submit an RMA.
Action: Submit an RMA