S-Series : After rebooting the switch the "ip ospf network point-to-point" command is missing from the config for non default VRFs

« Go Back

Information

 
TitleS-Series : After rebooting the switch the "ip ospf network point-to-point" command is missing from the config for non default VRFs
Symptoms
  • After rebooting the switch the "ip ospf network point-to-point" command is missing from the config for non default VRFs
  • Does not affect the Global VRF
  • If the original interface commands except point-to-point were configured in an image prior to  07_99_14_0004 and then upgraded
  • Then after upgrade  added point-to-point config
  • The point-to-point command will be lost after reboot
Environment
  • S-Series
  • Firmware 8.42.xx
  • Firmware 8.62.xx
  • VRF
  • Point-to-point OSPF network
Cause
This can result from upgrading from a very old version (pre version 8) of the software without doing the save config/restore. This should have been done at upgrade between the major versions. 


 
Resolution
1. Save the  config file ( show config outfile ... )
2. reload that file on version 8  (configure slot1/... )
3. Requires reset.

 