TitleS-Series Bonded SSA rebooted twice with <3>Dune[2.interrupt] messages in the log.
Symptoms
SSA rebooted twice with message below:
Message 20/285 Syslog Message 08.62.01.0034 08/18/2018 22:06:15 <3>Dune[2.interrupt]0x014811a4 0x014811a4 0x014a1a88 0x0156e068 0x018841d8 0x018a4720 0x015766bc 0x014a0aa8
0x004727b4 0x00000518 0x00000004 0xeeeeeeee 0x0076433c 0x01c83da4 0xeeeeeeee
Environment
  • S-Series
  • Firmware 08.62.01.0034
Cause
Both units show power loss. Unit one was out for under a minute unit two was out for 27 minutes
 
Message 18/285 System Init 08.62.01.0034 08/18/2018 22:34:41
The software system has successfully completed initialization
and is entering its normal operational mode.

==============================================================================
Message 19/285 Informational 08.62.01.0034 08/18/2018 22:33:07

Device was last fully operational in user mode: 27 minutes, 17 seconds a
go. Last reset caused by: power loss.



 
Resolution
Check power source for issues