S-Series: Error after upgrade - restoreNvPortData(256): nonvol_get(NONVOL_MAJOR_PIOA_DOT1DBASEPORT_ENTRY,1001) = 3

« Go Back

Information

 
TitleS-Series: Error after upgrade - restoreNvPortData(256): nonvol_get(NONVOL_MAJOR_PIOA_DOT1DBASEPORT_ENTRY,1001) = 3
Symptoms
 
  • Error Displays during bootup
  • Usually after upgrade or config restore
<165>Jul 15 09:23:57 10.3.0.3 BrdgMIB[1.tusrAppInit]restoreNvPortData(256): nonvol_get(NONVOL_MAJOR_PIOA_DOT1DBASEPORT_ENTRY,1001) = 3
<165>Jul 15 09:23:57 10.3.0.3 BrdgMIB[1.tusrAppInit]restoreNvPortData(258): nonvol_get(NONVOL_MAJOR_PIOA_DOT1DBASEPORT_ENTRY,1003) = 3
Environment
  • S-Series
  • Firmware All
Cause
Rare condition where historic change in config store can leave a duplicate entry that results in this error.
Resolution
This should not be indicative of a problem and is a display only issue
No further action needed 

Either ignore the warnings at boot/restore time or to stop them you  can create a config file, and reboot to it (configure <slot>/<file>) and that should clear the stale entries.

If you have any config loss accompanying this issue then please open a case with GTAC for further investigation